SE3000H-US |
SE3800H-US |
SE5000H-US |
SE6000H-US |
SE7600H-US |
OUTPUT |
Rated AC Power Output |
3000 |
3800 |
5000 |
6000 |
7600 |
VA |
Max. AC Power Output |
3000 |
3800 |
5000 |
6000 |
7600 |
VA |
AC Output Voltage Min.-Nom.-Max. (183 - 208 - 229) |
- |
- |
3 |
- |
- |
Vac |
AC Output Voltage Min.-Nom.-Max. (211 - 240 - 264) |
3 |
3 |
3 |
3 |
3 |
Vac |
AC Frequency (Nominal) |
59.3 - 60 - 60.5(1) |
Hz |
Maximum Continuous Output Current 208V |
- |
- |
24 |
- |
- |
A |
Maximum Continuous Output Current 240V |
12.5 |
16 |
21 |
25 |
32 |
A |
GFDI Threshold |
1 |
A |
Utility Monitoring, Islanding Protection, Country Configurable Thresholds |
Yes |
INPUT |
Maximum DC Power |
4650 |
5900 |
7750 |
9300 |
11800 |
W |
Transformer-less, Ungrounded |
Yes |
Maximum Input Voltage |
480 |
Vdc |
Nominal DC Input Voltage |
380 |
400 |
Vdc |
Maximum Input Current 208V |
- |
- |
15.5 |
- |
- |
Adc |
Maximum Input Current 240V |
8.5 |
10.5 |
13.5 |
16.5 |
20 |
Adc |
Max. Input Short Circuit Current |
45 |
Adc |
Reverse-Polarity Protection |
Yes |
Ground-Fault Isolation Detection |
600k Sensitivity |
Maximum Inverter Efficiency |
99 |
99.2 |
% |
CEC Weighted Efficiency |
99 |
% |
Nighttime Power Consumption |
< 2.5 |
W |
ADDITIONAL FEATURES |
Supported Communication Interfaces |
RS485, Ethernet, ZigBee (optional), Cellular (optional) |
Revenue Grade Data, ANSI C12.20 |
Optional(2) |
Rapid Shutdown - NEC 2014 and 2017 690.12 |
Automatic Rapid Shutdown upon AC Grid Disconnect |
STANDARD COMPLIANCE |
Safety |
UL1741, UL1699B, CSA C22.2, Canadian AFCI according to T.I.L. M-07 |
Grid Connection Standards |
IEEE1547, Rule 21(3), Rule 14 (HI) |
Emissions |
FCC Part 15 Class B |
INSTALLATION SPECIFICATIONS |
AC Output Conduit Size / AWG Range |
0.75-1" Conduit / 14-6 AWG |
DC Input Conduit Size / # of Strings / AWG Range |
0.75-1" Conduit /1-2 strings / 14-6 AWG |
Dimensions with Safety Switch (HxWxD) |
17.7 x 14.6 x 6.8 / 450 x 370 x 174 |
in / mm |
Weight with Safety Switch |
25.3 / 11.5 |
lb / kg |
Noise |
< 25 |
dBA |
Cooling |
Natural Convection |
Operating Temperature Range |
-13 to +140 / -25 to +60(4) (-40˚F / -40˚C option)(5) |
˚F / ˚C |
Protection Rating |
NEMA 3R (Inverter with Safety Switch) |